Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Kidney Int Rep ; 9(1): 152-161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312776

RESUMO

Introduction: Ultracyclists expose themselves to extreme physical challenges. This study aimed to elucidate the effects of ultracycling on electrolyte and fluid balance and investigate the potential occurrence of peripheral edema. Methods: A total of 4 clinical visits were performed before, during, and after a 6-day bicycle ride in 13 ultracyclists (5 female, 8 male) including serial laboratory analyses of blood and urine, bioelectrical impedance, and echocardiography. Throughout the ride, participants continuously tracked fluid intake, measured extremity circumferences daily, and self-tested urinary electrolytes using a point-of-care testing device. Portrait photos were judged by 20 physicians for occurrence of facial and eyelid edema. Results: Participants covered a mean distance of 1205 km and 19,417 vertical meters. From baseline to day 6, body weight remained stable (P = 0.479); however, body composition changed with increasing total body water (TBW) (+1.98 l ± 1.37, P = 0.003) and plasma volume (+18.86 % ± 10.7, P < 0.001). A significant increase in N-terminal pro brain natriuretic peptide (NT-proBNP) (+297.99 ng/l ± 190.42, P < 0.001) until day 6 indicates concomitant cardiac volume overload. Swelling of face and eyelids peaked on day 5 (both P ≤ 0.033). On recovery, changes partly resolved. Although urinary sodium concentration showed a nadir on day 4 (-32.18 mmol/l ± 23.88, P = 0.022), plasma osmolality (+5.69 mmosmol/kg ± 5.88, P = 0.004) and copeptin (+38.28 pg/ml ± 18.90, P < 0.001) increased steadily until day 6. Conclusion: Ultracycling over multiple days induces extracellular volume expansion, peripheral edema, and cardiac volume overload. Renal sodium and water retention is likely contributing to this condition.

2.
Eur Heart J Digit Health ; 4(3): 155-164, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37265873

RESUMO

Aims: We aimed to investigate the concordance between heart rate variability (HRV) derived from the photoplethysmographic (PPG) signal of a commercially available smartwatch compared with the gold-standard high-resolution electrocardiogram (ECG)-derived HRV in patients with cardiovascular disease. Methods and results: We prospectively enrolled 104 survivors of acute ST-elevation myocardial infarction, 129 patients after an ischaemic stroke, and 30 controls. All subjects underwent simultaneous recording of a smartwatch (Garmin vivoactive 4; Garmin Ltd, Olathe, KS, USA)-derived PPG signal and a high-resolution (1000 Hz) ECG for 30 min under standardized conditions. HRV measures in time and frequency domain, non-linear measures, as well as deceleration capacity (DC) were calculated according to previously published technologies from both signals. Lin's concordance correlation coefficient (ρc) between smartwatch-derived and ECG-based HRV markers was used as a measure of diagnostic accuracy. A very high concordance within the whole study cohort was observed for the mean heart rate (ρc = 0.9998), standard deviation of the averages of normal-to-normal (NN) intervals in all 5min segments (SDANN; ρc = 0.9617), and very low frequency power (VLF power; ρc = 0.9613). In contrast, detrended fluctuation analysis (DF-α1; ρc = 0.5919) and the square mean root of the sum of squares of adjacent NN-interval differences (rMSSD; ρc = 0.6617) showed only moderate concordance. Conclusion: Smartwatch-derived HRV provides a practical alternative with excellent accuracy compared with ECG-based HRV for global markers and those characterizing lower frequency components. However, caution is warranted with HRV markers that predominantly assess short-term variability.

3.
Nat Med ; 28(9): 1823-1830, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36031651

RESUMO

Digital smart devices have the capability of detecting atrial fibrillation (AF), but the efficacy of this type of digital screening has not been directly compared to usual care for detection of treatment-relevant AF. In the eBRAVE-AF trial ( NCT04250220 ), we randomly assigned 5,551 policyholders of a German health insurance company who were free of AF at baseline (age 65 years (median; interquartile range (11) years, 31% females)) to digital screening (n = 2,860) or usual care (n = 2,691). In this siteless trial, for digital screening, participants used a certified app on their own smartphones to screen for irregularities in their pulse waves. Abnormal findings were evaluated by 14-day external electrocardiogram (ECG) loop recorders. The primary endpoint was newly diagnosed AF within 6 months treated with oral anti-coagulation by an independent physician not involved in the study. After 6 months, participants were invited to cross-over for a second study phase with reverse assignment for secondary analyses. The primary endpoint of the trial was met, as digital screening more than doubled the detection rate of treatment-relevant AF in both phases of the trial, with odds ratios of 2.12 (95% confidence interval (CI), 1.19-3.76; P = 0.010) and 2.75 (95% CI, 1.42-5.34; P = 0.003) in the first and second phases, respectively. This digital screening technology provides substantial benefits in detecting AF compared to usual care and has the potential for broad applicability due to its wide availability on ordinary smartphones. Future studies are needed to test whether digital screening for AF leads to better treatment outcomes.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Criança , Atenção à Saúde , Eletrocardiografia , Feminino , Humanos , Masculino , Programas de Rastreamento , Smartphone
4.
Respirology ; 27(10): 903-904, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35836353

Assuntos
COVID-19 , Áustria , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...